R
ECON
ENMET Corporation
11
6.0 Specifications and Troubleshooting Tips
6.1 Specifications
Electrical Power Working Voltage
3.6V
DC
Lithium battery,1200 mAh Rechargeable
Working time continuous, non-alarm conditions
Combustible gas: Approximately 8 hours
Toxic gas: Approximately 30+ hours
Charge time 4 to 6 hours
Operation Temperature:
–20°C to +50°C
Relative Humidity
5 to 95% RH, non-condensing
Mechanical Dimensions:
2.4 x 3.9 x 1.3 inches(60 x 100 x 33 mm)
Weight:
5 oz. (140g) including battery
Ingress Protection IP 65
Approval Designed to be intrinsically safe
N
OTE
: All specifications stated in this manual may change without notice.
6.2 Troubleshooting Tips
ALFUNCTION
OSSIBLE
EASONS
OLUTIONS
Unable to Turn on the detector
low voltage Charge Battery
Detector Fault Contact ENMET Corporation
Circuit malfunction Contact ENMET Corporation
No reaction to the tested gas
Exhausted Sensor Replace Sensor
Circuit malfunction Contact ENMET Corporation
Inaccurate indication
Exhausted sensor Replace the sensor
Overdue Calibration Calibrate
Wrong time display
Exhausted battery Charge and reset the time
Electromagnetic disturb Reset the time
Zero calibration function failed Too much drift Calibrate or replace the sensor
7.0 Accessories Parts
Recon is supplied with a belt clip(4) and an alligator-type clip(1) with a D-ring(2). These can be attached to the instrument as
shown below.
010101Belt Clip & Alligator Type Clip Attached Alligator-Type Clip
D-Ring
1.
Alligator-Type Clip
4.
Belt Clip
Attached
3.
Fastening Screw